Specifications
Fire Brick Lined Front Loading Natural Draft Kilns

 

 

Model Number

DLB-50

 

Inside Volume -Cu.Ft.

67

 

Setting Space-Cu.Ft.

50

 


Setting Area-Inches

W D H
37x37x60

 

Inside Dimension-Inches

48x45x60

 

Outside Dimension-Inches

65x78x91

 

Instrumentation                    (Microprocessor Controller Optional Equipment)

DD1 Controller

 

Stacking Height-Inches

60

 

Temperature Range

0-2500� F.

 

Shelf Size-Inches Per Level

4-18x18 or
2-12x18 & 3-12x24

 

Maximum BTU/HR. Input

623,000

 

Maximum Gas Consumption CFH

750

 

Minimum Gas Pressure

6 Inches Water Column Pressure

 

Gas Line Inlet Inches

1-1/4

 

Number of Burners

10

 

Average Firing Time-Cone 06

6 Hours

 

Average Firing Time-Cone 10

8-10 Hours

 

Approximate Shipping Weight 

4,800 lbs.

 

Electrical hook-up required on all kilns. No extra charge for kilns firing with propane gas. Please specify.