Specifications
Fire Brick Lined Front Loading Natural Draft Kilns

 

 

Model Number

DLB-20

 

Inside Volume -Cu.Ft.

35

 

Setting Space-Cu.Ft.

20

 


Setting Area-Inches

W D H
38x24x40

 

Inside Dimension-Inches

48x32x40

 

Outside Dimension-Inches

63x62x73

 

Instrumentation                   (Microprocessor Controller  Optional Equipment)

DD1 Controller

 

Stacking Height-Inches

40

 

Temperature Range

0-2500� F.

 

Shelf Size-Inches Per Level

3-12x24

 

Maximum BTU/HR. Input

280,000

 

Maximum Gas Consumption CFH

300

 

Minimum Gas Pressure

6 Inches Water Column Pressure

 

Gas Line Inlet Inches

1

 

Number of Burners

8

 

Average Firing Time-Cone 06

6 Hours

 

Average Firing Time-Cone 10

8-10 Hours

 

Approximate Shipping Weight 

3,160 lbs.

 

Electrical hook-up required on all kilns. No extra charge for kilns firing with propane gas. Please specify.
Specifications subject to change without notice. Patent 4,531,910 
ETL Intertek Certified

 

Return to Brick Gas Kilns