Specifications
Fiber Lined Front Loading Natural Draft Kilns

 

 

Model Number

DL-36F

 

Inside Volume -Cu.Ft.

56

 

Setting Space-Cu.Ft.

36

 


Setting Area-Inches

W D H
37x37x48

 

Inside Dimension-Inches

48x42x48

 

Outside Dimension-Inches

60x74x78

 

Instrumentation                    (Microprocessor Controller  Optional Equipment)

DD1 Controller

 

Stacking Height-Inches

48

 

Temperature Range

0-2500� F

 

Shelf Size-Inches Per Level

4-18x18 or
2-12x18 & 3-12x24

 

Maximum BTU/HR. Input

449,000

 

Maximum Gas Consumption CFH

408

 

Minimum Gas Pressure

6 Inches Water Column Pressure

 

Gas Line Inlet Inches

1

 

Number of Burners

8

 

Average Firing Time-Cone 06

6 Hours

 

Average Firing Time-Cone 10

8-10 Hours

 

Approximate Shipping Weight 

3,000 lbs.

 

Electrical hook-up required on all kilns. No extra charge for kilns firing with propane gas. Please specify.
Specifications subject to change without notice. Patent 4,531,910 
ETL Intertek Certified

 

Return to Fiber Gas Kilns