| Specifications
Fiber
Lined Front Loading Natural Draft Kilns
|
| |
Model
Number |
DL-16F |
| |
Inside
Volume -Cu.Ft. |
27 |
| |
Setting
Space-Cu.Ft. |
16 |
| |
Setting Area-Inches
|
W
D H
28x28x36 |
| |
Inside
Dimension-Inches |
39x34x36 |
| |
Outside
Dimension-Inches |
54x63x65 |
| |
Instrumentation
(Microprocessor Controller Optional
Equipment) |
DD1
Controller |
| |
Stacking
Height-Inches |
36 |
| |
Temperature
Range |
0-2500�
F |
| |
Shelf
Size-Inches Per Level |
2-14x28
or 4-14x14 |
| |
Maximum
BTU/HR. Input |
200,000 |
| |
Maximum
Gas Consumption CFH |
181 |
| |
Minimum
Gas Pressure |
6
Inches Water Column Pressure |
| |
Gas
Line Inlet Inches |
3/4 |
| |
Number
of Burners |
6 |
| |
Average
Firing Time-Cone 06 |
6
Hours |
| |
Average
Firing Time-Cone 10 |
8
Hours |
| |
Approximate
Shipping Weight |
2,000
lbs. |
Electrical
hook-up required on all kilns. No extra charge for
kilns firing with propane gas. Please specify.
Specifications subject to change without notice.
Patent 4,531,910 ETL
Intertek Certified
|
|
|
|
|
|
|