Specifications - Fire Brick  Lined Natural Draft Shuttle Kiln (one car)

Model Number

DLB-82S

Inside Volume -Cu.Ft.

113

Setting Space-Cu.Ft.

82


Setting Area-Inches

W D H
38x74x51

Inside Dimension-Inches

51x79x51

Outside Dimension-Inches

67x105x83

Instrumentation                   (Microprocessor Controller Optional Equipment)

DD1 Controller

Stacking Height-Inches

51

Temperature Range

0-2500º F.

Shelf Size-Inches Per Level

9-12x24

Maximum BTU/HR. Input

984,000

Maximum Gas Consumption CFH

1,230

Minimum Gas Pressure

6 Inches Water Column Pressure

Gas Line Inlet Inches

1-1/4

Number of Burners

16

Average Firing Time-Cone 06

6 Hours

Average Firing Time-Cone 10

8-10 Hours

Approximate Shipping Weight 

6,000 lbs.

Electrical hook-up required on all kilns. No extra charge for kilns firing with propane gas. Please specify.
Specifications subject to change without notice. Patent 4,531,910 
CSA Certified
 