Specifications - Fire Brick Lined Front Loading Natural Draft Kilns

Model Number

DLB-40

Inside Volume -Cu.Ft.

60

Setting Space-Cu.Ft.

40


Setting Area-Inches

W D H
37x37x52

Inside Dimension-Inches

48x45x52

Outside Dimension-Inches

65x78x83

Instrumentation                      (Microprocessor Controller  Optional Equipment)

DD1 Controller

Stacking Height-Inches

52

Temperature Range

0-2500º F.

Shelf Size-Inches Per Level

4-18x18 or
2-12x18 & 3-12x24

Maximum BTU/HR. Input

499,000

Maximum Gas Consumption CFH

600

Minimum Gas Pressure

6 Inches Water Column Pressure

Gas Line Inlet Inches

1

Number of Burners

8

Average Firing Time-Cone 06

6 Hours

Average Firing Time-Cone 10

8-10 Hours

Approximate Shipping Weight 

4,600 lbs.

Electrical hook-up required on all models. No extra charge for kilns firing with propane gas. Please specify.
Specifications subject to change without notice. Patent 4,531,910 
CSA Certified