Specifications - Fire Brick Lined Front Loading Natural Draft Kilns

Model Number

DLB-16

Inside Volume -Cu.Ft.

27

Setting Space-Cu.Ft.

16


Setting Area-Inches

W D H
28x28x36

Inside Dimension-Inches

39x34x36

Outside Dimension-Inches

55x64x66

Instrumentation                         (Microprocessor Controller  Optional Equipment)

DD1 Controller

Stacking Height-Inches

36

Temperature Range

0-2500º F.

Shelf Size-Inches Per Level

4-14x14 or 2-14x28

Maximum BTU/HR. Input

200,000

Maximum Gas Consumption CFH

240

Minimum Gas Pressure

6 Inches Water Column Pressure

Gas Line Inlet Inches

1

Number of Burners

6

Average Firing Time-Cone 06

6 Hours

Average Firing Time-Cone 10

8-10 Hours

Approximate Shipping Weight 

2,600 lbs.

Electrical hook-up required on all models. No extra charge for kilns firing with propane gas. Please specify.
Specifications subject to change without notice. Patent 4,531,910 
CSA Certified

Back to Table